Home Product IMMUNOHISTOCHEMISTRY MICROSTACKER™ DETECTION SYSTEMS [RX] MicroStacker™ Mouse-on-Mouse HRP Polymer

[RX] MicroStacker™ Mouse-on-Mouse HRP Polymer

The MicroStacker™ technology allows well-controlled layered stacking of F(ab’) fragments of IgG secondary antibody and peroxidase enzymes on a micro-polymer scaffold, which results in a compact polymeric structure with superior sensitivity compared to other conventional HRP polymers with bulky dextran backbones. This system avoids the use of streptavidin and biotin, and therefore eliminates non-specific staining as a result of endogenous biotin. Herein, the Mouse-on-Mouse Polymer comprises of specially engineered anti-Mouse secondary antibody to eliminate the high backgrounds caused by endogenous mouse antibodies in mouse tissues.

Product Features

🛒Online Order

 

Product Features

 Original MicroStacker™ Technology – Utilizes proprietary technology for superior detection of mouse primary antibodies on mouse tissue

 Special Treatment – Reduces reactivity with endogenous mouse IgG, minimizing background interference

 No Blocking Required – Eliminates the need for endogenous mouse IgG blocking steps, simplifying protocols

 Reduced Background – Provides lower background and clearer staining compared to conventional Mouse-on-Mouse methods

 

Recommended Protocol

 Primary Antibody: Room temperature, 30-60 minutes

 Detection Polymer: Room temperature, 12 minutes

 DAB Incubation: 5 minutes

 

MicroStacker™ Technology Platform

MicroStacker™ Mouse-on-Mouse Polymer is a biotin-free, polymeric horseradish peroxidase (HRP) secondary antibody conjugate system designed to detect mouse primary antibodies on mouse tissue. This system features specially engineered anti-mouse secondary antibodies to minimize high background caused by endogenous mouse IgG.

Celnovte’s proprietary MicroStacker™ technology uses micro-polymer scaffolds to enable orientation-controlled attachment of Fab’ fragments to the poly-HRP core. This proprietary Fab’ labeling method prevents the antibody binding site from being blocked during bioconjugation, enhancing the polymer’s sensitivity. The compact polymeric structure penetrates all cellular compartments, ensuring consistent staining of nuclear, cytoplasmic, and membranous antigens.

The biotin-free detection system prevents background staining from endogenous biotin. Additionally, the use of Fab’ fragments instead of whole IgG reduces non-specific binding to endogenous Fc receptors, further minimizing background. This results in superior sensitivity and specificity compared to traditional HRP polymers with bulky dextran backbones.

 

Immunohistochemistry detection scheme for MicroStacker™ Mouse-on-Mouse Polymer Kit
MicroStacker™ Mouse-on-Mouse Polymer Detection Workflow

 

Experimental Group

MicroStackerTM Mouse-on-Mouse Polymer Detection Kit

 

Comparison with Detection Polymers

Compared with international leading brand detection systems.

 

Staining Results

Mouse Spleen – SMA, 1% PEG

Mouse spleen stained with SMA antibody using MicroStacker™ kit
Staining of Mouse Spleen with SMA-1% PEG using MicroStacker™

 

Mouse Kidney – SMA, 1% PEG

Mouse kidney stained with SMA antibody using MicroStacker™ kit
Staining of Mouse Kidney with SMA-1% PEG using MicroStacker™

🛒Online Order

Specification

 

Cat # Product Name Size Components
CSM1004 MicroStacker™ Mouse-on-Mouse HRP Polymer 20mL, 100mL, 1000mL Anti-mouse HRP Polymer
CSK2001 MicroStacker™ Mouse-on-Mouse HRP Polymer Detection Kit 200T, 1000T 1. Anti-mouse HRP Polymer