COMPRAR
Lar Produto Imuno -histoquímica Sistemas de detecção MicroStacker ™ [Manual] MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step

[Manual] MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step

MicroStacker™ Polymer Detection System is a biotin-free, polymeric horseradish peroxidase (HRP)- secondary antibody conjugate system for the detection of mouse and rabbit primary antibody on formalin-fixed, paraffin-embedded (FFPE) tissues in an immunohistochemistry (IHC) procedure. The innovative MicroStacker™ technology allows well-controlled layered stacking of antibodies and peroxidase enzymes on a micro-polymer scaffold. This technique results in a compact polymeric structure that easily penetrates to all cellular compartments. Plus, the system utilizes F(ab’) fragments of IgG secondary antibody instead of the whole IgG, which avoids the background caused by non-specific binding of whole IgG to endogenous Fc receptors. Compared to the MicroStacker™ Polymer Detection System, Universal, the Enhanced kit comes with the HRP polymer at a higher degree of polymerization, thus higher sensitivity.

Recursos do produto

MicroStacker™ Polymer Detection Kit, Enhanced – 2-Step IHC Detection System

🛒Online Order

 

MicroStacker™ Enhanced is a biotin-free polymer-based HRP secondary antibody detection system optimized for formalin-fixed paraffin-embedded (FFPE) tissue sections. It’s designed to detect mouse and rabbit primary antibodies in IHC workflows.

Compared to the standard MicroStacker™ Universal kit, the Enhanced version features a higher degree of polymerization, offering greater sensitivity and improved signal intensity.

 

Product Highlights

  • Biotin-free, polymeric HRP-conjugated secondary antibody
  • Uses F(ab’) fragment to reduce background staining
  • Compact polymer structure allows deep tissue penetration
  • Ideal for mouse-on-mouse detection
  • Enhanced signal intensity for low-expression targets

 

Recommended Manual IHC Protocol

  • Deparaffinization: Xylene and graded alcohols to water
  • Bloqueio da peroxidase: 5 min block, rinse with wash buffer
  • Antigen Retrieval: Follow primary antibody datasheet
  • Primary Antibody Incubation: 30–60 min at RT
  • Detection Polymer Incubation: 30 min at RT
  • DAB Development: 5 min using ready-to-use solution
  • Contraindicação: Hematoxilina

Use TBS-T or PBS-T as wash buffer. Store reagents at 2–8°C. Do not freeze.

 

Side-by-Side Comparison: Experimental Results

Part 1: HER2 (Rabbit mAb) on Breast Tissue

  • REAL EnVision™ Detection System
  • MicroStacker™ Universal
  • MicroStacker™ Enhanced

REAL EnVision detection - HER2 IHC
REAL EnVision™

MicroStacker Universal detection - HER2 IHC
MicroStacker™ Universal

MicroStacker Enhanced detection - HER2 IHC
MicroStacker™ Enhanced

Part 2: D2-40 (Mouse mAb) on Esophagus Tissue

  • REAL EnVision™
  • EnVision™ Flex + Mouse Linker
  • MicroStacker™ Enhanced

REAL EnVision detection - D2-40
REAL EnVision™

EnVision Flex + Mouse Linker detection - D2-40
EnVision™ Flex + Mouse Linker

MicroStacker Enhanced detection - D2-40
MicroStacker™ Enhanced

 

Especificação

Cat # Nome do produto Size Componentes
SD3206 MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step (4 components) 200T, 1000T

1 Linker,Rabbit-anti-Mouse

2 Anti-Rabbit HRP-Polymer

3 DAB Chromogen (20x)

4 DAB Substrate Buffer

SD3207 MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step (5 components) 200T, 1000T

1 Linker,Rabbit-anti-Mouse

2 Anti-Rabbit HRP-Polymer

3 DAB Chromogen (20x)

4 DAB Substrate Buffer

5 Peroxidase Block

SD3208 MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step (6 components) 200T, 1000T

1 Linker,Rabbit-anti-Mouse

2 Anti-Rabbit HRP-Polymer

3 DAB Chromogen (20x)

4 DAB Substrate Buffer

5 Peroxidase Block

6 Hematoxylin

Mais informações

Produto relacionado

Entre em contato

Se você tiver uma consulta ou algum feedback para nós, preencha o formulário abaixo para entrar em contato com nossa equipe.

principal