製品 免疫組織化学 Microstacker™検出システム [Manual] MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step

[Manual] MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step

MicroStacker™ Polymer Detection System is a biotin-free, polymeric horseradish peroxidase (HRP)- secondary antibody conjugate system for the detection of mouse and rabbit primary antibody on formalin-fixed, paraffin-embedded (FFPE) tissues in an immunohistochemistry (IHC) procedure. The innovative MicroStacker™ technology allows well-controlled layered stacking of antibodies and peroxidase enzymes on a micro-polymer scaffold. This technique results in a compact polymeric structure that easily penetrates to all cellular compartments. Plus, the system utilizes F(ab’) fragments of IgG secondary antibody instead of the whole IgG, which avoids the background caused by non-specific binding of whole IgG to endogenous Fc receptors. Compared to the MicroStacker™ Polymer Detection System, Universal, the Enhanced kit comes with the HRP polymer at a higher degree of polymerization, thus higher sensitivity.

製品機能

MicroStacker™ Polymer Detection Kit, Enhanced – 2-Step IHC Detection System

🛒Online Order

 

MicroStacker™ Enhanced is a biotin-free polymer-based HRP secondary antibody detection system optimized for formalin-fixed paraffin-embedded (FFPE) tissue sections. It’s designed to detect mouse and rabbit primary antibodies in IHC workflows.

Compared to the standard MicroStacker™ Universal kit, the Enhanced version features a higher degree of polymerization, offering greater sensitivity and improved signal intensity.

 

Product Highlights

  • Biotin-free, polymeric HRP-conjugated secondary antibody
  • Uses F(ab’) fragment to reduce background staining
  • Compact polymer structure allows deep tissue penetration
  • Ideal for mouse-on-mouse detection
  • Enhanced signal intensity for low-expression targets

 

Recommended Manual IHC Protocol

  • Deparaffinization: Xylene and graded alcohols to water
  • ペルオキシダーゼ・ブロック 5 min block, rinse with wash buffer
  • Antigen Retrieval: Follow primary antibody datasheet
  • Primary Antibody Incubation: 30–60 min at RT
  • Detection Polymer Incubation: 30 min at RT
  • DAB Development: 5 min using ready-to-use solution
  • 反対票: ヘマトキシリン

Use TBS-T or PBS-T as wash buffer. Store reagents at 2–8°C. Do not freeze.

 

Side-by-Side Comparison: Experimental Results

Part 1: HER2 (Rabbit mAb) on Breast Tissue

  • REAL EnVision™ Detection System
  • MicroStacker™ Universal
  • MicroStacker™ Enhanced

REAL EnVision detection - HER2 IHC
REAL EnVision™

MicroStacker Universal detection - HER2 IHC
MicroStacker™ Universal

MicroStacker Enhanced detection - HER2 IHC
MicroStacker™ Enhanced

Part 2: D2-40 (Mouse mAb) on Esophagus Tissue

  • REAL EnVision™
  • EnVision™ Flex + Mouse Linker
  • MicroStacker™ Enhanced

REAL EnVision detection - D2-40
REAL EnVision™

EnVision Flex + Mouse Linker detection - D2-40
EnVision™ Flex + Mouse Linker

MicroStacker Enhanced detection - D2-40
MicroStacker™ Enhanced

 

仕様

Cat # 製品名 Size コンポーネント
SD3206 MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step (4 components) 200T, 1000T

1 Linker,Rabbit-anti-Mouse

2 Anti-Rabbit HRP-Polymer

3 DAB Chromogen (20x)

4 DAB Substrate Buffer

SD3207 MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step (5 components) 200T, 1000T

1 Linker,Rabbit-anti-Mouse

2 Anti-Rabbit HRP-Polymer

3 DAB Chromogen (20x)

4 DAB Substrate Buffer

5 Peroxidase Block

SD3208 MicroStacker™ Polymer Detection Kit, Enhanced, 2-Step (6 components) 200T, 1000T

1 Linker,Rabbit-anti-Mouse

2 Anti-Rabbit HRP-Polymer

3 DAB Chromogen (20x)

4 DAB Substrate Buffer

5 Peroxidase Block

6 Hematoxylin

詳細

関連製品

連絡してください

お問い合わせやフィードバックがある場合は、以下のフォームに記入して、チームにお問い合わせください。

トップ